Aquafine Aqua 2 User Manual

 

Turn on the electrical power to the UV unit. Turn the power off until actual operational start up begins. Rapid successive cycling of the power to the ballasts can cause premature failure of the system components. UV lamp operational display panel To verify that all the UV lamps are operating properly, your UV treatment unit has been provided with a UV Lamp Operational Display Panel. The panel consists of as many LED indicators as there are ultraviolet lamps. Each LED indicator is electrically connected to the lamp circuitry of a specific UV lamp.

  1. Aqua 2 Water Stove
  2. Aqua Fine Aqua 2 Water Softener Manual

Do not allow the flow rate to exceed the maximum rated capacity. DO NOT ELECTRICALLY CYCLE THE UV UNIT MORE THAN THREE (3) ON/OFF CYCLES IN A 24-HOUR PERIOD.

Aquafine aqua 2 water softener manual Don't hurry to select the location before inputting the password as there will be mahual success in that. Use instead the 'Save As' button in the New Archive dialog, this does have the desired effect. With the new archive created and password protected, you can proceed to adding your files and folders. Aquafine aqua ii 34u water softener how toset the regenerator timing - Home question.

Aqua 2 Water Stove

Should any UV lamp fail to operate electrically, the corresponding LED will automatically turn 'off'. Each UV lamp is numbered at the end of the UV treatment chamber, and the corresponding LED light carries the same number on the display panel; thus, if one or more LED lights fail to operate, you can easily determine which specific lamp requires attention. We recommend you monitor the LED Panel daily to ensure proper performance. Running time meter Your ultraviolet treatment unit has been furnished with a Running Time Meter, located on the front instrument panel. This non-resettable running time meter will log up to 99,999 hours.

Standard UV Lamps, DE 254 nm Mauve Size: 30' Length....... Amd radeon hd 8330 driver windows 7. 3084LM Validated UV Lamps, DE 254 nm Green Size: 30' Length....... SL-1 & MP-2 SL -- TOC REDUCTION 21. Standard UV Lamps, DE 185 nm Blue Size: 30' Length....... 3087 Validated UV Lamps, DE 185 nm Yellow Size: 30' Length.......

This manual covers the servicing and general maintenance requirements for Aquafine Ultraviolet Water Treatment equipment. Read this manual and.

Please read and adhere to these comments carefully. Release the pressure in the UV treatment chamber before attempting to remove the protective covers and sealing items. Disconnect all power to the UV unit before servicing. The unit operates on high voltage and should only be serviced by qualified personnel. Do not look at the lighted blue ultraviolet lamps. Do not operate the ultraviolet lamps outside of the UV treatment chamber. Exposure can severely burn and damage eyes and skin.

ANY OF THE FOLLOWING CONDITIONS WILL VOID THE EQUIPMENT WARRANTY. Failure to connect proper electrical service to unit. Failure to properly ground the unit. Failure to eliminate excessive vibration, piping movement, or water hammer.

4 Treatment Chamber... 4 Refer to this nameplate decal on your unit when ordering parts or service. Warranty Information... 4-5 Unit Installation Where to Install the Unit... 6 How to Protect Your Unit... 6 Operating Pressure... 6 Hot Water Sanitization Information..

Supply the unit with the correct voltage and frequency as indicated on the nameplate decal, ensuring the unit is wired in accordance with local electrical codes. Properly ground the unit.

Aqua Fine Aqua 2 Water Softener Manual

Avoid touching the lamp tip after you remove the rubber lamp socket. This is a shock hazard.

Install the new ballast, securing it with the bolt removed earlier. Tighten the bolt with 5/32 L-shaped hex wrench. Reconnect ballast. Restore the power to the UV unit by turning the unit isolator switch to the 'ON' position or by closing the upstream switch or breaker. Remove the lamp sockets. Remove the ultraviolet lamps from inside the quartz sleeves.